CE Certificate Anesthesia Machine( ACM619)
Anesthesia Machine
Supply gas pressure 280kPa-600kPa
evaporator concentration 0.2%~5%
Oxygen concentration ≥21%
O2 flush 25L/min~75L/min
Gas pressure alarm (electromotion) 0.185~0.22MPa
ANESTHESIA VENTILATOR
The main characters
Application Adult,Child and neonate
Driven mode Pneumatically driven and electrically controlled, time switch
Ventilation modes VC-IPPV,VC-SIPPV,VC-SIGH,VC-SIMV,PC-IPPV,PC-SIMV,PC-SIPPV,VC-PSV,PC-PSV, PR-IPPV,PR-SIPPV, PR-SIMV,PR-PSV,Manual
Respiratory rate 1bpm~100bpm, tolerance ±15%
Tidal volume working range 20mL~1600mL ,continuously adjustable.
I/E ratio 1/0.3~1/8
Triggering sensitivity 0.0kPa~2.0 kPa,tolerance±0.1kPa
Waveform Double waveforms displaying for pressure-time and flow-time (optional: volume-time, CO2-time, pressure volume loop, flow volume loop)
Tih 0-60% inspiratory time
Inspiratory pressure 0.3kPa~6.0kPa,tolerance±0.1kPa
ps/ramp 0.02s~2.00s
Supply pressure 0.3kPa~6.0 kPa,tolerance±0.1kPa
Triggering flowrate OFF,0.1LPM~20LPM,tolerance±0.5LPM
ELECTRIC PEEP OFF,0.3kPa~3.0 kPa,tolerance±0.1kPa
PS end flow 1%~60% maximal flow
triggering window 20%~95%
Pressure Limit 0.9kPa~7.9 kPa
Monitoring parameters
Respiratory rate, I/E ratio, breath holding time, Tidal volume, Minute volume, Ppeak, Average Pressure, minimum pressure, PEEP, FIO2 concentration,
Optional (FICO2 concentration, ETCO2 concentration, BIS), compliance.
Alarms
Airway pressure, Tidal volume, Minute volume, Oxygen concentration, Power failure, Apnea, Flow sensor failure, Respiratory rate, Flow sensor failure, Optional(ETCO2 concentration,FICO2 concentration), Lower gas pressure, sustained pressure, complete pipeline, PEEP, Silence time for alarm ≤120s.
ANESTHESIAMACHINE Flowmeter
O2(two tubes) 0.05~1L/min ,1.0~10L/min
N2O (two tubes) 0.05~1L/min,1.0~10L/min
Air (two tubes) 0.05~1L/min,1.0~10L/min
ORC device The proportion between O2 and N2O can be continuously adjustable to assure the O2 concentration above21%.
Other function
Altitude compensation, O2 compensation, N2O compensation, big screen display, alarm volume adjustment, Start self-test, compliance compensation, leakage compensation
Power less than50VA
Machine noise £65db
Input power supply AC 110/220V input
Output power supply DC 24V output, tolerance±1%
Power supply Interface RS485
Anti-jamming requirement it can resist the power conduct and radiation of other equipments